SB76

Fim de produção

De pressão sem amplificador

SB76

Fim de produção

De pressão sem amplificador

Características principais
  • Direct surface strain reading like bonded strain gages
  • Very high accuracy
  • High linearity on tension and compression
Produto de reposição
SB76-VDA I VDA268
De pressão com amplificador digital

Especificações técnicas

Visão geral

Press-on strain sensors measures the surface-strain directly at the mounting location, similar to bonded strain gages.

The SB76 presses strain gages under the stainless protective foil that strongly onto the surface to be measured that friction replaces the bonding normally used to fix strain gages.

The mounting is very fast, and the strain gage is protected.

The sensor can not be overloaded.

The sensors do not need to be recalibrated once they have been replaced or remounted.

They need a cyclical reset (for cycles >5min.).

Our amplifier can handle the occuring large offset range.

  • Direct surface strain reading like bonded strain gages
  • Very high accuracy
  • High linearity on tension and compression
  • Without integrated amplifier (passiv)
  • For Dynamic applications
  • Used on Presses, injection moulding and die-casting machines
  • Quick and easy mounting
  • Can not be overloaded (offset may occur)
  • External amplifier recommended (e.g. MBA100; VDA, Monitor DU-1D)